Tech Spec
Vian Power C5 | ||
On / Off Heat Pump | ||
KW Out | C.O.P @ | |
CAPACITY @ ℃ | On / Off model | 100 % Power |
Plus 25 ℃ | 4.78 | 6.16 |
Plus 20 ℃ | 4.23 | 5.45 |
Plus 15 ℃ | 3.68 | 4.72 |
Plus 10 ℃ | 3.16 | 4.14 |
Plus 05 ℃ | 2.64 | 3.53 |
0.0 ℃ | 2.12 | 2.94 |
Minus 5 ℃ | 1.68 | 2.31 |
Minus 10 ℃ | / | / |
Capacity KW 27/24 (DB/WB) | 5kw | |
Usage | Hot Tub | |
Type | On/Off | |
Max Power Draw | 0.806 KW | |
Power Supply | 220-240 V 50HZ Single Phase | |
Power Cable | 5mtrs H07RN-F cable | |
Ambient Temp Operating Range | minus 5℃ to plus 40 ℃ | |
Heating Range | 15℃ to 40℃ | |
Cooling Function | ✗ | |
Max Water Volume | 15m3 (15,000 ltrs) | |
Refridgerant | R32 | |
Compressor | Rotary | |
Heat Exchanger | Titanium | |
Gas Control | Capillary | |
Sound @ 1m DB | 48 | |
Required Flow Rate | 2.5 mh3 (41.6 lpm) | |
Input Line Control | ✗ | |
Pump Power Circuit 1.59 (A) max | ✗ | |
WI-FI | ✗ | |
Unit Size (L-D-H) mm | 505 / 360 / 545 | |
Net Weight kg | 27 KG |